TTR sheathed thermocouple
浏览: 发布日期:2022-04-27



Product overview 

The TTR sheathed thermocouple is of short thermal response time, dynamic error reduced, large measurement scope, high mechanical strength and good pressure-resistant properties. It has many advantages (such as being bent, resistance to high pressure, quick thermal response time and being sturdy and durable). Like industrial fabricated thermocouple, it, as the sensor for temperature measurement, is usually used in conjunction with display instrument, recording instrument and electronic regulator and can be also used as temperature-sensing element of fabricated thermocouple. It can be used to directly measure the temperature of liquid, steam and gas medium and solid surface within the scope of 0℃~1300℃ in all kinds of production processes. 


Product features 

● Temperature measurement scope and allowable error 

Graduation number

Tolerance level

1

11

Allowable error value

Temperature measurement range ℃

Allowable error value

Temperature measurement range ℃

K

±1.5℃

-415

±2.5℃

-40~+333

±0.004(t)

375~1000

±0.0075(t)

333~1200

N

±1.5℃

-40~+375

±2.5℃

-40~+333

±0.0041(t)

375~1000

±0.0075(t)

333~1200

E

±1.5℃

-40~+375

±2.5℃

-40~+333

±0.004(t)

375~800

±0.004(t)

333-900

J

±1.5℃

-40~+375

±1.5℃

-40~+333

±0.004(t)

375~750

±0.004(t)

333~750

1

±1.5℃

-165

±1℃

-173

±0.004(t)

125~350

±0.00751(t)

133~1000

S

±1℃

0~+1100

±2.5℃

0~600

±11+0.003(t-1100)

1100~1600

±0.0025(t)

600~1600


● Thermocouple wire diameter and material 

Thermocouple wire form

Single type

Double type

Diameter of bushing

Ø2  Ø3  Ø4  Ø5  Ø6  Ø8

Ø3  Ø4  Ø5  Ø6  Ø8

Bushing material

E, J and T

1Cr18Ni9T

1Cr18N/9Ti

K and N

1Cr18Ni9Ti  GH3030

1Cr1BNi9Ti  GH3030

S

GH3039

GH3039 


Product model selection 

TTR

sheathed thermocouple



Temperature-sensing element material

      M Nichrosi-nisiloy     N Nickel-chromium-nisiloy E Nickel-chromium-copper nickel           J iron-platinum-copper nickel         T Copper-copper nickel      


Logarithm of thermocouple wire

     1 Single        2 Double


Installation type

2 Fixing thread    3 Fixed flange               4 Flexible pipe joint type          5 Fixing thread conical protection tube  

   6 Straight pipe joint type    7 Fixing threaded pipe joint type       8 Movable threaded pipe joint type    0 No fixed device


Junction box type

      E Explosion-proof type


Diameter of the protective tube

      S  Ø16mm     D Special customization


Working end form

G Variable cross-section